(02) 8021 3517 Send your job →
ACTFLEX ULTRA TC pack
● TDS-ULTRATC · Rev 4 · 12 November 2026

ACTFLEX ULTRA TC UV topcoat membrane

100% solids two-component aliphatic polyurethane UV topcoat and standalone membrane

UV-stable, trafficable 1 : 1 finish over ACTFLEX 929 membranes, or a standalone membrane over EP250.

100% solids1 : 1 mixPot life 40 min
1 : 1Mix ratio
40 kg kitPack
0.3–0.6 mmTopcoat film
1.2 mmStandalone
≈ 43 m²Coverage
40 minPot life
● The numbers

ACTFLEX ULTRA TC coverage, coats and cure times

100% solids two-component aliphatic polyurethane. It is the UV-stable face over cured ACTFLEX 929 SL and 929 HV, or a standalone trafficable membrane at 1.2 mm over two coats of ACTFLEX EP250.

Mix ratio
1 : 1Part A to Part B, by volume and by weight · TDS p2
Pack
40 kg kit20 kg Part A + 20 kg Part B · TDS p2
Topcoat film
0.3–0.6 mmone coat over 929 SL or 929 HV, by duty · TDS p3
Standalone
1.2 mm2 coats over 2 coats of ACTFLEX EP250 · TDS p3
Coverage
≈ 43 m²per kit at 0.6 mm, practical; 21 m² at 1.2 mm · TDS p3
Pot life
40 mintypicalat 25°C, shorter in heat · TDS p2
Recoat
12–24 htypicalminimum 12 hours, maximum 24 hours · TDS p2
Heavy traffic
7 daystypicalafter final coat; light foot traffic at 24 hours · TDS p4
Apply at
10–30°Csubstrate 3°C above dew point, RH below 80% · TDS p1

From the FORSPEC data sheet, TDS-ULTRATC · Revision 4 · 12 November 2026. Times are at 25°C and 50% relative humidity unless the data sheet says otherwise. Typical = FORSPEC’s own typical value, not a laboratory-certified one.

● Is it right for the job

Where ACTFLEX ULTRA TC is used

Use it for

  • UV-stable topcoat over cured ACTFLEX 929 SL and 929 HV
  • Standalone trafficable membrane over 2 coats of EP250, 1.2 mm DFT
  • Exposed trafficable walls and floors needing a UV-stable finish
  • Plant rooms, walkways, balconies and exposed horizontal surfaces
  • New UV-stable wearing face on solvent-based polyurethane membranes

Know before you start

  • Not a primer: standalone use needs two coats of ACTFLEX EP250 first
  • Not for permanent immersion, pools, tanks or negative-side pressure
  • Never dilute, and no part-mixing unless both parts are weighed accurately
● On site

How to apply ACTFLEX ULTRA TC

  1. 01

    Prepare

    Concrete cured 28 days, ground or shot blasted to an open profile, moisture 4.5% or less. Over 929 SL or 929 HV: fully cured, clean, sound and well adhered.

  2. 02

    Prime

    Standalone system only: two coats of ACTFLEX EP250, then apply 12 to 24 hours after the final EP250 coat. Beyond 24 hours, abrade, remove all dust and re-prime with ACTFLEX EP250.

  3. 03

    Mix

    Condition both parts to 15–25°C. Empty Part B into Part A and mix at 300–400 rpm for at least 3 minutes, decant and remix briefly. Apply straight away.

  4. 04

    Apply

    Notched squeegee and back-roll, or roller. Wet film equals dry film, so check with a wet film gauge. Topcoat: one coat at 0.3 or 0.6 mm. Standalone: two coats to 1.2 mm.

  5. 05

    Recoat

    Second coat after at least 12 hours and within 24. Beyond 24 hours, abrade, remove dust, solvent-wipe with FORSPEC EPOXY CLEANER and let it flash off.

  6. 06

    Cure

    Light foot traffic from 24 hours, heavy foot traffic from 7 days. Flood test a standalone membrane after full cure, for 24 hours.

A short guide from the data sheet. Read the full ACTFLEX ULTRA TC TDS before you start.

Drawings for the systems it goes in

FORSPEC standard details as PDF and DXF. Each sheet is a generic detail: the specification names the products.

● Questions

ACTFLEX ULTRA TC questions

Is ACTFLEX ULTRA TC a topcoat or a membrane?

Both. Over cured ACTFLEX 929 SL or 929 HV it is the UV-stable topcoat. Over two coats of ACTFLEX EP250 at 1.2 mm total DFT it is a standalone trafficable membrane.

How much do I need?

A 40 kg kit covers about 86 m² at 0.3 mm, 43 m² at 0.6 mm and 21 m² at 1.2 mm in practice, allowing 10% for wastage. Theoretical yields are 95, 48 and 24 m².

Can I drive on it?

Yes, for cars and light vehicles once it is fully cured (7 days). It is also rated for heavy foot traffic. It is not designed for forklifts, heavy vehicles or steel-wheeled loads.

How long before I recoat?

At least 12 hours and within 24 hours at 25°C and 50% RH. After 24 hours, abrade and clean the surface first.

How long can I work with a mixed kit?

Pot life is 40 minutes at 25°C and 50% RH, and it shortens sharply as temperature rises. Mix only what you can lay in that time.

Is it certified?

The data sheet lists no certificate or test report. All performance values are typical FORSPEC R&D values, determined to the test standards it names. Do not rely on them for engineering design without written confirmation from FORSPEC Technical Services.

● Documents

ACTFLEX ULTRA TC data sheet

Always work from the current data sheet. Every FORSPEC TDS and SDS →

Specify it. Or buy it.

Send the drawings or photos and FORSPEC comes back with the system, the details and the quantities. Or find a FORSPEC stockist for ACTFLEX ULTRA TC.

Send us your job →☎